Commission Delegated Regulation (EU) 2023/2534 of 13 July 2023 supplementing Regu... (32023R2534)
Commission Delegated Regulation (EU) 2023/2534 of 13 July 2023 supplementing Regu... (32023R2534)
COMMISSION DELEGATED REGULATION (EU) 2023/2534
of 13 July 2023
supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with regard to energy labelling of household tumble dryers and repealing Commission Delegated Regulation (EU) No 392/2012
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Obligations of suppliers
Article 4
Obligations of dealers
Article 5
Measurement and calculation methods
Article 6
Verification procedure for market surveillance purposes
Article 7
Review
Article 8
Repeal
Article 9
Transitional measures
Article 10
Entry into force and application
ANNEX I
Definitions
ANNEX II
Energy efficiency class, acoustic airborne noise emission class and condensation efficiency class
1.
ENERGY EFFICIENCY CLASS
|
Energy efficiency class |
Energy Efficiency Index |
|
A (most efficient) |
EEI ≤ 43 |
|
B |
43 < EEI ≤ 50 |
|
C |
50 < EEI ≤ 60 |
|
D |
60 < EEI ≤ 70 |
|
E |
70 < EEI ≤ 85 |
|
F |
85 < EEI ≤ 100 |
|
G (least efficient) |
EEI > 100 |
2.
ACOUSTIC AIRBORNE NOISE EMISSION CLASS
|
Acoustic airborne noise emission class |
Noise (dB(A)) |
|
A |
LWA ≤ 60 |
|
B |
60 < LWA ≤ 64 |
|
C |
64 < LWA ≤ 68 |
|
D |
LWA &amp;amp;amp;gt; 68 |
3.
CONDENSATION EFFICIENCY CLASS
|
Condensation efficiency class |
Weighted condensation efficiency |
|
A |
Ct ≥ 94 |
|
B |
88 ≤ Ct < 94 |
|
C |
82 ≤ Ct < 88 |
|
D |
Ct < 82 |
ANNEX III
Label
A.
Label for condenser tumble dryers
1. LABEL FOR CONDENSER TUMBLE DRYERS
Figure 1
2. LABEL DESIGN FOR CONDENSER TUMBLE DRYERS
Figure 2
B.
Label for non-condenser tumble dryers
1. LABEL FOR NON-CONDENSER TUMBLE DRYERS
Figure 3
2. LABEL DESIGN FOR NON-CONDENSER TUMBLE DRYERS
Figure 4
ANNEX IV
Measurement and calculation methods
1. ENERGY EFFICIENCY INDEX
2. CONDENSATION EFFICIENCY
3. LOW POWER MODES
4. ACOUSTIC AIRBORNE NOISE EMISSION
ANNEX V
Product information sheet
|
Supplier’s name or trade mark (1) , (3): |
|||||
|
Supplier’s address (1) , (3): |
|||||
|
Model identifier (1): |
|||||
|
Technology of tumble dryer |
[electric air-vented, electric condenser, gas-fired] |
||||
|
General product parameters: |
|||||
|
Parameter |
Value |
Parameter |
Value |
||
|
Rated capacity(2) (kg) |
x,x |
Dimensions(1) , (3) in cm |
Height |
x |
|
|
Width |
x |
||||
|
Depth |
x |
||||
|
Energy Efficiency Index (EEI)(2) |
x,x |
Energy efficiency class(2) |
[A/B/C/D/E/F/G](4) |
||
|
Condensation efficiency (%)(2) (if applicable) |
xx |
Condensation efficiency class (if applicable)(2) |
[A/B/C/D](4) |
||
|
Weighted energy consumption in kWh per drying cycle(8). Actual energy consumption will depend on how the appliance is used. |
x,xx |
|
|
||
|
Programme duration(2) (hours:minutes) |
Rated capacity |
x:xx |
Type |
[built-in/free-standing] |
|
|
Half |
x:xx |
||||
|
Acoustic airborne noise emission(2) (dB(A) re 1 pW) |
x |
Acoustic airborne noise emission class(2) |
[A/B/C/D](4) |
||
|
Off-mode (if applicable) (W) |
x,xx |
Standby mode (if applicable) (W) |
x,xx |
||
|
Delay start (W) (if applicable) |
x,xx |
Networked standby (W) (if applicable) |
x,xx |
||
|
For household tumble dryers equipped with a heat pump, the chemical name or the accepted industry designation of the refrigerant gas used, without prejudice to Regulation (EU) No 517/2014 on fluorinated greenhouse gases(1) (1) , (3). |
|
||||
|
Weblink to information on spare parts availability for professional repairers and end users(1) (3) (5) |
https://xxx |
||||
|
Weblink to repair instructions for end-users(1) (3) (6) |
https://xxx |
||||
|
Weblink to indicative pre-tax prices(1) (3) (7) |
https://xxx |
||||
|
Minimum duration of the guarantee offered by the supplier(1) (3) |
|
||||
|
Additional information (1) (3) |
|||||
|
Link to the supplier’s website, where the information in point 6 of Annex II to Commission Regulation (EU) 2023/2533(3) (2)is found: |
|||||
ANNEX VI
Technical documentation
|
PARAMETER |
UNIT |
VALUE |
|
Rated capacity for the eco programme, at 0,5 kg intervals (c) |
kg |
X,X |
|
Energy consumption of the eco programme at full load (Edry ) |
kWh/drying cycle |
X,XX |
|
Energy consumption of the eco programme at partial load (Edry,½ ) |
kWh/drying cycle |
X,XX |
|
Weighted energy consumption of the eco programme (EtC ) |
kWh/drying cycle |
X,XX |
|
Standard energy consumption of the eco programme (SEC ) |
kWh/drying cycle |
X,XX |
|
Energy Efficiency Index (EEI) |
- |
X,X |
|
Programme duration for the eco programme at full load (Tdry ) |
h:min |
X:XX |
|
Programme duration for the eco programme at partial load (Tdry½ ) |
h:min |
X:XX |
|
Weighted programme duration for the eco programme (Tt ) |
h:min |
X:XX |
|
Average condensation efficiency of the eco programme at full load (Cdry ) (if applicable) |
% |
XX |
|
Average condensation efficiency of the eco programme at partial load (Cdry½ ) (if applicable) |
% |
XX |
|
Weighted condensation efficiency of the eco programme (Ct ) (if applicable) |
% |
XX |
|
Acoustic airborne noise emission during the eco programme |
dB(A) with respect to 1 pW |
X |
|
Power consumption in off mode (Po ) (if applicable) |
W |
X,XX |
|
Power consumption in standby mode (Psm ) (if applicable) |
W |
X,XX |
|
Does ‘standby mode’ include the display of information? |
- |
Yes/No |
|
Power consumption in ‘standby mode’ in condition of networked standby (Pnsm) (if applicable) |
W |
X,XX |
|
Power consumption in delay start (Pds ) (if applicable) |
W |
X,XX |
|
PARAMETER |
UNIT |
VALUE |
|
Rated capacity for the eco programme, at 0,5 kg intervals (c) |
kg |
X,X |
|
Gas consumption of the eco programme at full load (Egdry ) |
kWh/drying cycle |
X,XX |
|
Gas consumption of the ‘eco’ programme at partial load (Egdry,½ ) |
kWh/drying cycle |
X,XX |
|
Auxiliary electricity consumption of the eco programme at full load |
kWh/drying cycle |
X,XX |
|
Auxiliary electricity consumption of the eco programme at partial load |
kWh/drying cycle |
X,XX |
|
Weighted energy consumption of the eco programme (EtC ) |
kWh/drying cycle |
X,XX |
|
Standard energy consumption of the eco programme (SEC ) |
kWh/drying cycle |
X,XX |
|
Energy Efficiency Index (EEI) |
- |
X,X |
|
Programme duration for the eco programme at full load (Tdry ) |
h:min |
XXX |
|
Programme duration for the eco programme at partial load (Tdry½ ) |
h:min |
XXX |
|
Weighted programme duration for the eco programme (Tt ) |
h:min |
XXX |
|
Acoustic airborne noise emission during the eco programme |
dB(A) re 1 pW |
X |
|
Power consumption in off mode (Po ) (if applicable) |
W |
X,XX |
|
Power consumption in standby mode (Psm ) (if applicable) |
W |
X,XX |
|
Does ‘standby mode’ include the display of information? |
- |
Yes/No |
|
Power consumption in standby mode in condition of networked standby (Pnsm ) (if applicable) |
W |
X,XX |
|
Power consumption in ‘delay start’ (Pds ) (where applicable) |
W |
X,XX |
ANNEX VII
Information to be provided in visual advertisements, in technical promotional material and in distance selling, except distance selling on the internet
Figure 5
Coloured/monochrome left arrow, with range of energy efficiency classes indicated
ANNEX VIII
Information to be provided in the case of distance selling on the internet
Figure 6
Coloured left arrow, with range of energy efficiency classes indicated
ANNEX IX
Verification procedure for market surveillance purposes
|
Parameter |
Validity criteria |
||
|
Average final moisture content of the eco programme μt |
The determined value shall be measured and calculated and be lower than 1,5 %. |
||
|
Parameter |
Verification tolerances |
||
|
Edry and Edry½ |
The determined value* shall not exceed the declared value of Edry and Edry½ by more than 6 %. |
||
|
Egdry and Egdry½ |
The determined value* shall not exceed the declared value of Egdry and Egdry½ by more than 6 %. |
||
|
Egdry,a and Egdry½,a |
The determined value* shall not exceed the declared value of Egdry,a and Egdry½,a by more than 6 %. |
||
|
Ct |
The determined value* shall not be less than the declared value of Ct by more than 6 %. |
||
|
Tdry and Tdry½ |
The determined value* shall not exceed the declared value of Tdry and Tdry½ by more than 6 %. |
||
|
Po |
The determined value* of power consumption Po shall not exceed the declared value by more than 0,10 W. |
||
|
Psm |
The determined value* of power consumption Psm shall not exceed the declared value by more than 10 % if the declared value is higher than 1,00 W, or by more than 0,10 W if the declared value is lower than or equal to 1,00 W. |
||
|
Pds |
The determined value* of power consumption Pds shall not exceed the declared value by more than 10 % if the declared value is higher than 1,00 W, or by more than 0,10 W if the declared value is lower than or equal to 1,00 W. |
||
|
Acoustic airborne noise emissions |
The determined value* shall not exceed the declared value by more than 2 dB re 1 pW. |
||
|
|||