Commission Regulation (EC) No 1882/2006 of 19 December 2006 laying down methods o... (32006R1882)
Commission Regulation (EC) No 1882/2006 of 19 December 2006 laying down methods o... (32006R1882)
COMMISSION REGULATION
(EC) No 1882/2006
of 19 December 2006
laying down methods of sampling and analysis for the official control of the levels of nitrates in certain foodstuffs
(Text with EEA relevance)
Article 1
Article 2
ANNEX
METHODS OF SAMPLING, SAMPLE PREPARATION AND ANALYSIS FOR OFFICIAL CONTROL OF LEVELS OF NITRATES IN CERTAIN FOODSTUFFS
A. GENERAL PROVISIONS
A.1 Scope
A.2 Definitions
A.3 General provisions
A.3.1 Personnel
A.3.2 Material to be sampled
A.3.3 Precautions to be taken
A.3.4 Incremental samples
A.3.5 Preparation of the aggregate sample
A.3.6 Replicate samples
A.3.7 Packaging and transmission of samples
A.3.8 Sealing and labelling of samples
A.4 Different types of lots
B. METHOD OF SAMPLING
B.1 Sampling in the field
B.2 Sampling of lots of spinach, lettuce, baby foods and processed cereal based food for infants and young children on the market
|
Weight of lot (in kg) |
Minimum number of incremental samples to be taken |
Aggregate sample minimum weight (kg) |
|
< 50 |
3 |
1 |
|
50 to 500 |
5 |
1 |
|
> 500 |
10 |
1 |
|
Number of packages or units in the lot |
Number of packages or units to be taken |
Aggregate sample minimum weight (kg) |
|
1 to 25 |
1 package or unit |
1 |
|
26 to 100 |
about 5 %, at least 2 packages or units |
1 |
|
> 100 |
about 5 %, at maximum 10 packages or units |
1 |
B.3 Sampling at retail stage
B.4 Assessment of compliance of a lot or sublot
C. SAMPLE PREPARATION
D. METHOD OF ANALYSIS, REPORTING OF RESULTS AND LABORATORY CONTROL REQUIREMENTS
D.1 Definitions
D.2 General requirements
D.3 Specific requirements
D.3.1 Extraction procedure
D.3.2 Performance criteria
|
Criterion |
Concentration range |
Recommended value |
Maximum permitted value |
|
Recovery |
< 500 mg/kg |
60-120 % |
|
|
≥ 500 mg/kg |
90-110 % |
|
|
|
Precision RSDR |
All |
As derived from Horwitz Equation |
2 × value derived from Horwitz Equation |
|
Precision RSDr may be calculated as 0,66 times Precision RSDR at the concentration of interest. |
|||