FOURTH COMMISSION DIRECTIVE
of 11 October 1985
on the approximation of the laws of the Member States relating to methods of analysis necessary for checking the composition of cosmetic products
(85/490/EEC)
Article 1
Article 2
Article 3
ANNEX
IDENTIFICATION AND DETERMINATION OF GLYCEROL l-(4-AMINOBENZOATE)
A. IDENTIFICATION
1. SCOPE AND FIELD OF APPLICATION
2. PRINCIPLE
3. REAGENTS
4. APPARATUS
5. PROCEDURE
5.1.
Sample preparation
5.2.
Thin layer chromatography
5.3.
Development
B. DETERMINATION
1. SCOPE AND FIELD OF APPLICATION
2. DEFINITION
3. PRINCIPLE
4. REAGENTS
Standard Solution |
Alpha-monoglyceryl 4-aminobenzoate |
Ethyl 4-aminobenzoate |
Ethyl 4-hydroxybenzoate |
|||
(μg/ml)(1) |
ml (4.11)(1) |
(μg/ml)(1) |
ml (4.12) |
(μg/ml)(1) |
ml (4.13) |
|
I |
8 |
2 |
8 |
2 |
50 |
10 |
II |
16 |
4 |
12 |
3 |
50 |
10 |
III |
24 |
6 |
16 |
4 |
50 |
10 |
IV |
40 |
10 |
20 |
5 |
50 |
10 |
5. APPARATUS
6. PROCEDURE
6.1.
Sample preparation
6.2.
Chromatography
6.3.
Calibration curve
7. CALCULATION
8. REPEATABILITY(2)
9. NOTES
DETERMINATION OF CHLOROBUTANOL
1. SCOPE AND FIELD OF APPLICATION
2. DEFINITION
3. PRINCIPLE
4. REAGENTS
5. APPARATUS
6. PROCEDURE
6.1.
Preparation of sample
6.2. Gas chromatography conditions
Column |
I |
II |
Material |
Glass |
Stainless steel |
Length |
1,80 m |
3 m |
Diameter |
3 mm |
3 mm |
Stationary phase |
10 % Carbowax 20 M TPA on Gaschrom Q 80-100 mesh |
5 % OV 17 on Chromosorb WAW DMCS 80-100 mesh |
Conditioning |
2 to 3 days at 190 oC |
|
Temperature: |
|
|
— injector |
200 oC |
150 oC |
— column |
150 oC |
100 oC |
— detector |
200 oC |
150 oC |
Carrier gas |
Nitrogen |
Argon/methane (95/5 v/v) |
Flowrate |
35 ml/min |
35 ml/min |
6.3.
Standard curve
7. CALCULATION
8. REPEATABILITY(3)
IDENTIFICATION AND DETERMINATION OF QUININE
A. IDENTIFICATION
1. SCOPE AND FIELD OF APPLICATION
2. PRINCIPLE
3. REAGENTS
4. APPARATUS
5. PROCEDURE
5.1.
Preparation of the sample
5.2.
Thin layer chromatography
5.3.
Development
Alkaloid |
RF |
Quinine |
0,20 |
Quinidine |
0,29 |
Cinchonine |
0,33 |
Cinchonidine |
0,27 |
Hydroquinidine |
0,17 |
B. DETERMINATION
1. SCOPE AND FIELD OF APPLICATION
2. DEFINITION
3. PRINCIPLE
4. REAGENTS
5. APPARATUS
6. PROCEDURE
6.1.
Sample preparation
6.2.
Chromatography
6.3.
Calibration curve
7. CALCULATION
8. REPEATABILITY(4)
IDENTIFICATION AND DETERMINATION OF INORGANIC SULPHITES AND HYDROGEN SULPHITES
SCOPE AND FIELD OF APPLICATION
A. IDENTIFICATION
1. PRINCIPLE
2. REAGENTS
3. APPARATUS
4. PROCEDURE
B. DETERMINATION
1. DEFINITION
2. PRINCIPLE
3. REAGENTS
4. APPARATUS
5. PROCEDURE
6. CALCULATION
7. REPEATABILITY(5)
Sulphurdioxide distillation apparatus according to Tanner
All dimensions in mm
IDENTIFICATION AND DETERMINATION OF CHLORATES OF THE ALKALI METALS
SCOPE AND FIELD OF APPLICATION
A. IDENTIFICATION
1. PRINCIPLE
2. REAGENTS
3. APPARATUS
4. PROCEDURE
5. EVALUATION
Halates |
RF |
Iodate |
0 to 0,2 |
Bromate |
0,5 to 0,6 |
Chlorate |
0,7 to 0,8 |