COMMISSION DECISION (EU) 2015/1402
of 15 July 2015
determining the European Union position with regard to a decision of the management entities under the Agreement between the Government of the United States of America and the European Union on the coordination of energy-efficiency labelling programmes for office equipment on the revision of specifications for computers included in Annex C to the Agreement
(Text with EEA relevance)
Sole Article
ANNEX
DRAFT DECISION
of …
the Management entities under the Agreement between the Government of the United States of America and the European Union on the coordination of energy-efficiency labelling programmes for office equipment on the revision of specifications for computers included in Annex C of the Agreement
ANNEX
ANNEX C
PART II TO THE AGREEMENT
V. COMPUTER SPECIFICATIONS (VERSION 6.1)
1.
Definitions
2.
Scope
2.1.
Included Products
2.2.
Excluded Products
3.
Qualification Criteria
3.1.
Significant Digits and Rounding
3.2.
General Requirements
Loading Condition (Percentage of Nameplate Output Current) |
Minimum Efficiency |
Minimum Power Factor |
20 % |
0,82 |
— |
50 % |
0,85 |
— |
100 % |
0,82 |
0,90 |
3.3.
Power Management Requirements
Mode or Mode Transition |
Requirement |
Desktops |
Integrated Desktops |
Portable All-In-Ones |
Notebooks |
Small-scale Servers |
Slates/Tablets |
Thin Clients |
Workstations |
||||||||
System Sleep Mode(1) |
|
Yes |
Yes |
Yes |
Yes |
No |
N/A |
Yes |
Yes |
||||||||
Display Sleep Mode |
Display Sleep Mode shall be set to activate after no more than 15 minutes of user inactivity. |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
||||||||
Wake on LAN (WOL)(1) |
|
Yes |
Yes |
Yes |
Yes |
Yes |
N/A |
Yes |
Yes |
||||||||
Wake Manage-ment(1) |
Computers with Ethernet capability that are shipped through enterprise channels shall:
|
Yes |
Yes |
Yes |
Yes |
Yes |
N/A |
Yes |
Yes |
3.4.
User Information Requirements
3.5.
Requirements for Desktop, Integrated Desktop, and Notebook Computers
Equation 1:
TEC Calculation (E
TEC
) for Desktop, Integrated Desktop, Thin Client and Notebook Computers
Mode Weighting |
Conventional (%) |
Full Network Connectivity |
|||
Base Capability (%) |
Remote Wake (%) |
Service Discovery/Name Services (%) |
Full Capability (%) |
||
TOFF |
45 |
40 |
30 |
25 |
20 |
TSLEEP |
5 |
15 |
28 |
36 |
45 |
TLONG_IDLE |
15 |
12 |
10 |
8 |
5 |
TSHORT_IDLE |
35 |
33 |
32 |
31 |
30 |
Mode Weighting |
Conventional (%) |
Full Network Connectivity |
|||
Base Capability (%) |
Remote Wake (%) |
Service Discovery/Name Services (%) |
Full Capability (%) |
||
TOFF |
25 |
25 |
25 |
25 |
25 |
TSLEEP |
35 |
39 |
41 |
43 |
45 |
TLONG_IDLE |
10 |
8 |
7 |
6 |
5 |
TSHORT_IDLE |
30 |
28 |
27 |
26 |
25 |
Equation 2:
E
TEC_MAX
Calculation for Desktop, Integrated Desktop, and Notebook Computers
Power Supply Type |
Computer Type |
Minimum Efficiency at Specified Proportion of Rated Output Current(2) |
Minimum Average Efficiency(3) |
AllowancePSU |
|||
10 % |
20 % |
50 % |
100 % |
||||
IPS |
Desktop |
0,81 |
0,85 |
0,88 |
0,85 |
— |
0,015 |
0,84 |
0,87 |
0,90 |
0,87 |
— |
0,03 |
||
Integrated Desktop |
0,81 |
0,85 |
0,88 |
0,85 |
— |
0,015 |
|
0,84 |
0,87 |
0,90 |
0,87 |
— |
0,04 |
||
EPS |
Notebook or Desktop |
0,83 |
— |
— |
— |
0,88 |
0,015 |
0,84 |
— |
— |
— |
0,89 |
0,03 |
||
Integrated Desktop |
0,83 |
— |
— |
— |
0,88 |
0,015 |
|
0,84 |
— |
— |
— |
0,89 |
0,04 |
Category Name |
Graphics Capability(4) |
Desktop or Integrated Desktop |
Notebook |
||
Performance Score, P (5) |
Base Allowance |
Performance Score, P v |
Base Allowance |
||
0 |
Any Graphics dGfx ≤ G7 |
P ≤ 3 |
69,0 |
P ≤ 2 |
14,0 |
I1 |
Integrated or Switchable Graphics |
3 < P ≤ 6 |
112,0 |
2 < P ≤ 5,2 |
22,0 |
I2 |
6 < P ≤ 7 |
120,0 |
5,2 < P ≤ 8 |
24,0 |
|
I3 |
P > 7 |
135,0 |
P > 8 |
28,0 |
|
D1 |
Discrete Graphics dGfx ≤ G7 |
3 < P ≤ 9 |
115,0 |
2 < P ≤ 9 |
16,0 |
D2 |
P > 9 |
135,0 |
P > 9 |
18,0 |
Function |
Desktop |
Integrated Desktop |
Notebook |
||
TECMEMORY (kWh)(6) |
0,8 |
||||
TECGRAPHICS (kWh)(7) |
Graphics Category(8) |
G1 (FB_BW ≤ 16) |
36 |
14 |
|
G2 (16< FB_BW ≤ 32) |
51 |
20 |
|||
G3 (32 < FB_BW ≤ 64) |
64 |
26 |
|||
G4 (64 < FB_BW ≤ 96) |
83 |
32 |
|||
G5 (96 < FB_BW ≤ 128) |
105 |
42 |
|||
G6 (FB_BW > 128; Frame Buffer Data Width < 192 bits) |
115 |
48 |
|||
G7 (FB_BW > 128; Frame Buffer Data Width ≥ 192 bits |
130 |
60 |
|||
TECSWITCHABLE (kWh)(9) |
0,5 × G1 |
N/A |
|||
TECEEE (kWh)(10) |
8,76 × 0,2 × (0,15 + 0,35) |
8,76 × 0,2 × (0,10 + 0,30) |
|||
TECSTORAGE (kWh)(11) |
26 |
2,6 |
|||
TECINT_DISPLAY (kWh)(12) |
N/A |
8,76 × 0,35 × (1 + EP) × (4 × r + 0,05 × A) |
8,76 × 0,30 × (1 + EP) × (2 × r + 0,02 × A) |
Equation 3:
Calculation of Allowance for Enhanced-performance Integrated Displays
EP = |
0, |
No Enhanced Performance Display |
0,3, |
Enhanced Performance Display, d < 27 |
|
0,75, |
Enhanced Performance Display, d ≥ 27 |
3.6.
Requirements for Slates/Tablets and Portable All-In-One Computers
3.7.
Requirements for Workstations
Equation 4:
P
TEC
Calculation for Workstations
TOFF |
TSLEEP |
TLONG_IDLE |
TSHORT_IDLE |
35 % |
10 % |
15 % |
40 % |
Equation 5:
P
TEC_MAX
Calculation for Workstations
3.8.
Requirements for Small-scale Servers
Equation 6:
Calculation of P
OFF_MAX
for Small-scale Servers
POFF_BASE (watts) |
POFF_WOL (watts) |
1,0 |
0,4 |
Equation 7:
Calculation of P
IDLE_MAX
for Small-scale Servers
PIDLE_BASE (watts) |
PIDLE_HDD (watts) |
24,0 |
8,0 |
3.9.
Requirements for Thin Clients
Equation 8:
Calculation of E
TEC_MAX
for Thin Clients
Adder |
Allowance (kWh) |
TECBASE |
60 |
TECGRAPHICS |
36 |
TECWOL |
2 |
4.
Testing
4.1.
Test Methods
Product Type or Component |
Test Method |
All |
ENERGY STAR Test Method for Computers, Rev. August-2014 |
4.2.
Number of Units Required for Testing
4.3.
International Market Qualification
4.4.
Customer Software and Management Service Pre-Provisioning
5.
User Interface
6.
Effective Date
Appendix A
SAMPLE CALCULATIONS
TOFF |
25 % |
TSLEEP |
35 % |
TLONG_IDLE |
10 % |
TSHORT_IDLE |
30 % |
Category Name |
Graphics Capability |
Notebook |
|
Performance Score, P |
Base Allowance |
||
I1 |
Integrated or Switchable Graphics |
2 < P ≤ 5,2 |
22,0 |
TOFF |
TSLEEP |
TLONG_IDLE |
TSHORT_IDLE |
35 % |
10 % |
15 % |
40 % |
TEST METHODS (REVISION AUGUST 2014)
1.
Overview
2.
Applicability
3.
Definitions
4.
Test Setup
4.1.
Test Setup and Instrumentation
Market |
Voltage |
Voltage Tolerance |
Maximum Total Harmonic Distortion |
Frequency |
Frequency Tolerance |
Europe, Australia, New Zealand |
230 V ac |
+/– 1,0 % |
2,0 % |
50 Hz |
+/– 1,0 % |
Market |
Voltage |
Voltage Tolerance |
Maximum Total Harmonic Distortion |
Frequency |
Frequency Tolerance |
Europe, Australia, New Zealand |
230 V ac |
+/– 4,0 % |
5,0 % |
50 Hz |
+/– 1,0 % |
5.
Test Conduct
5.1.
Guidance for Implementation of EN 62623
5.2.
Preparing Display Luminance of Notebooks, Integrated Desktops, Slates/Tablets and Portable All-In-One Computers
6.
Test Procedures for all Products
6.1.
UUT Preparation
6.2.
Sleep Mode Testing
6.3.
Long Idle Mode Testing
6.4.
Short Idle Mode Testing
6.5.
Off Mode Testing
6.6.
Additional Testing For Reporting
7.
Test Procedures for Workstations
7.1.
Maximum Power Test
Benchmark |
Website |
Linpack |
http://www.netlib.org/linpack/ |
SPECviewperf |
http://www.spec.org/benchmarks.html#gpc |
7.2.
Benchmark Test
Benchmark |
Website |
Linpack |
http://www.netlib.org/linpack/ |
SPECviewperf |