COMMISSION RECOMMENDATION
of 18 November 2014
on the procedure for demonstrating the level of compliance of existing railway lines with the basic parameters of the technical specifications for interoperability
(2014/881/EU)
ANNEX
1.
Introduction
1.1.
Technical Scope
1.2.
Geographical Scope
1.3.
Definitions
2.
Procedure for demonstrating compliance with the technical specifications for Interoperability for existing lines
2.1.
Purpose
2.2.
Procedure for demonstrating the level of compliance with the basic parameters of the TSI
2.2.3. Technical documentation
2.2.5. EI declaration of demonstration
2.2.6. Technical file
2.3.
Characteristics to be assessed
Characteristics to be assessed (INF TSI) |
Existing line not subject to EC verification |
Particular assessment procedures |
1 |
2 |
|
Structure gauge (4.2.3.1) |
X |
6.2.4.1 |
Distance between track centres (4.2.3.2) |
X |
6.2.4.2 |
Maximum gradients (4.2.3.3) |
X |
|
Minimum radius of horizontal curve (4.2.3.4) |
X |
6.2.4.4 |
Minimum radius of vertical curve (4.2.3.5) |
X |
6.2.4.4 |
Nominal track gauge (4.2.4.1) |
X |
6.2.4.3 |
Cant (4.2.4.2) |
X |
6.2.4.4 |
Cant deficiency (4.2.4.3) |
X |
6.2.4.4 6.2.4.5 |
Abrupt change of cant deficiency (4.2.4.4) |
X |
6.2.4.4 |
Equivalent conicity (4.2.4.5) |
X |
6.2.4.6 |
Railhead profile for plain line (4.2.4.6) |
n.a |
6.2.4.7 |
Rail inclination (4.2.4.7) |
X |
|
Design geometry of switches and crossings (4.2.5.1) |
X |
6.2.4.8 |
Use of swing nose crossings (4.2.5.2) |
X |
6.2.4.8 |
Maximum unguided length of fixed obtuse crossings (4.2.5.3) |
X |
6.2.4.8 |
Track resistance to vertical loads (4.2.6.1) |
X |
6.2.5 |
Longitudinal track resistance (4.2.6.2) |
X |
6.2.5 |
Lateral track resistance (4.2.6.3) |
X |
6.2.5 |
Resistance of new bridges to traffic loads (4.2.7.1) |
n.a. |
|
Equivalent vertical loading for new earthworks and earth pressure effects (4.2.7.2) |
n.a. |
|
Resistance of new structures over or adjacent to tracks (4.2.7.3) |
n.a |
|
Resistance of existing bridges and earthworks to traffic loads (4.2.7.4) |
X |
6.2.4.10 |
The immediate action limit for alignment (4.2.8.1) |
n.a. |
|
The immediate action limit for longitudinal level (4.2.8.2) |
n.a. |
|
The immediate action limit for track twist (4.2.8.3) |
n.a. |
|
The immediate action limit of track gauge as an isolated defect (4.2.8.4) |
n.a. |
|
The immediate action limit for cant (4.2.8.5) |
n.a |
|
The immediate action limit for switches and crossings (4.2.8.6) |
n.a. |
|
Usable length of platforms (4.2.9.1) |
X |
|
Platform height (4.2.9.2) |
X |
|
Platform offset (4.2.9.3) |
X |
6.2.4.11 |
Track layout along platforms (4.2.9.4) |
X |
|
Maximum pressure variation in tunnels (4.2.10.1) |
X |
6.2.4.12 |
Effect of crosswinds (4.2.10.2) |
X |
6.2.4.13 |
Ballast pick-up (4.2.10.3) |
Open point |
|
Location markers (4.2.11.1) |
X |
|
Equivalent conicity in service (4.2.11.2) |
n.a. |
|
Toilet discharge (4.2.12.2) |
X |
6.2.4.14 |
Train external cleaning facilities (4.2.12.3) |
X |
6.2.4.14 |
Water restocking (4.2.12.4) |
X |
6.2.4.14 |
Refuelling (4.2.12.5) |
X |
6.2.4.14 |
Electric shore supply (4.2.12.6) |
X |
6.2.4.14 |
Application of Interoperability Constituents |
n.a. |
|
Characteristics to be assessed (ENE TSI) |
Existing line not subject to EC verification |
Particular assessment procedures |
1 |
2 |
|
Voltage and frequency (4.2.3) |
X |
|
Parameters relating to supply system performance (4.2.4) |
X |
6.2.4.1 |
Current capacity, DC systems, trains at standstill (4.2.5) |
X |
6.1.4.2 |
Regenerative braking (4.2.6) |
X |
6.2.4.2 |
Electrical protection coordination arrangements (4.2.7) |
X |
6.2.4.3 |
Harmonics and dynamic effects for AC traction power supply systems (4.2.8) |
X |
6.2.4.4 |
Geometry of the overhead contact line (4.2.9) |
X |
|
Pantograph gauge (4.2.10) |
X |
|
Mean contact force (4.2.11) |
X |
|
Dynamic behaviour and quality of current collection (4.2.12) |
X |
6.1.4.1, 6.2.4.5 |
Pantograph spacing for overhead contact line design (4.2.13) |
X |
|
Contact wire material (4.2.14) |
X |
|
Phase separation sections (4.2.15) |
X |
|
System separation sections (4.2.16) |
X |
|
Protective provisions against electric shock (4.2.18) |
X |
6.2.4.6 |
Maintenance rules (4.5) |
X |
6.2.4.7 |